EMV-APP01 
Multi-function I/O Extension Card 
Instruction Sheet 
‹
 
Please thoroughly read this instruction sheet before installation and putting it 
into use. 
‹
 
The content of this instruction sheet and the driver file may be revised 
without prior notice. Please consult our distributors or download the most 
updated instruction version at http://www.delta.com.tw/industrialautomation. 
X
Function Explanation
 
EMV-APP01 is optional I/O extension card for VFD-VE series of AC motor drive. 
Due to communication via RS-485 communication port (COM1), to ensure 
normal communication, please set COM1 communication protocol (Pr 09-04) to 
‘’8, N, 1 for RTU ’’ regardless of switch for high or low baud rate. 
Switch f or  hi gh/lo w b a ud  ra te
C ommu ni cati on  In dicato r
Power In dica tor
RS48 5 Po rt
An al og Si gn al  Common
Po wer O utpu t
Multi -f un ctio n 
Inpu t Terminal
Anal og O ut put 
Termi na l
Multi -f un ctio n 
Outp ut Termina l
Mu lti-f unctio n
Ou tput Commo n
 
NOTE
 
When switching baud rate, firstly you should disconnect RS-485 cable, then switch 
for high or low baud rate and set AC motor drive baud rate (Pr 09-01) to correspond 
with the switch’s baud rate. Only if the user does as the description above, you can 
switch baud rate successfully. If you don’t disconnect RS-485 cable firstly and switch 
for high or low baud rate directly, you still can see ERROR LED displays normal 
communication, whereas, actually the communication fails, even if AC motor drive 
baud rate (Pr 09-01) is corresponding to the switch’s baud rate. 
Terminal 
Symbol 
Explanation 
POWER 
Power Indicator. If the connection between EMV-APP01 and AC 
motor drive is right, this LED will be steadily on. 
ERROR 
Communication Indicator. If the EMV-APP01 can communicate 
with AC motor drive normally, this LED will be on; if not, it will 
blink. 
HIGH/LOW Switch 
for 
high/low baud rate 
HIGH: Set EMV-APP01’s baud rate to 115200 
LOW: Set EMV-APP01’s baud rate to 9600 
5V 
Power Output: 5VDC/500mA Max 
GND 
Analog Signal Common 
NOTE
 
This terminal is only used with the terminals 5V, SO1, SO2, 
MI7~MIB on EMV-APP01. DO NOT confuse with the control 
terminal “DCM” on AC motor drive. 
SO1-GND 
SO2-GND 
Analog Output Terminal: 0~10.0V (Output Current: 2mA Max) 
Analog output value is defined by Pr.03-21 and Pr.03-24. 
Terminal 
Symbol 
Explanation 
MI7~MIB Multi-function 
Input 
Terminal 
Refer to Pr.02-23 to Pr.02-27 for programming the multi-function 
inputs. 
For example: MI7-GND 
ON: the activation current is 6.5mA. 
OFF: leakage current tolerance is 10μA. 
MO3~MOA  Multi-function Output Terminal (Photocoupler) 
AC motor drive output various signals by open collector, such as 
AC drive operating, frequency attained, overload indication and 
so on. Refer to Pr.02-35 to Pr.02-42 for programming the 
multi-function outputs. 
MO3~MOA-MCM
MO3
~
MOA
MCM
Max: 48Vdc/50mA
Internal Circuit
 
MCM 
Multi-function Output Common 
Max: 48Vdc/50mA 
NOTE
 
This terminal is only used with “MO3” ~ “MOA” terminal on 
EMV-APP01. DO NOT confuse with the control terminal “MCM” on 
AC motor drive. 
Y
Dimension
 
 
Z
Wiring Diagram
 
Anal og Si gna l  Common
Power O utput
R efer  to Pr.0 2-3 5 to  Pr.02 -42 
for programming
Refer  to Pr.03-21 and  Pr.03-24 
for programming
R efer  to Pr.0 2-2 3 to  Pr.02 -27 
for programming
 
When wiring, please refer to Parameter Group 02 and 03 in Chapter 4 
Parameters for programming the multi-function inputs/outputs. The user could 
choose suitable setting functions to meet your own needs. 
 
EMV-APP01
多功能擴充卡說明書
 
‹
 
請詳細閱讀下列說明後才使用本產品,以確保使用安全。
 
‹
 
由於產品精益求精,當內容規格有所修正時,請洽詢代理商或至台達網站
(http://www.delta.com.tw/industrialautomation )下載最新版本。 
X
功能說明
 
多功能擴充卡(
EMV-APP01)是專為 VFD-VE 系列產品所設計的選購品。藉由
RS-485 通訊接口(COM1)與交流馬達驅動器作使用,為了確保通訊使用正常,無
論多功能擴充卡(
EMV-APP01)的波特率切換開關(高速/低速),都需要將驅動
(COM1)通訊格式(09-04)設置在 8,N,1 RTU 模式。 
電源 指示 燈
通訊 指示 燈
多功 能輸 出端 子
多功 能輸 入端 子
類比 輸出 端子
RS485通訊口
輸出 電源
類比 信號 共同 端子
多功 能輸 出共 同端
高 低波 特率切 換開 關
/
 
NOTE
 
當要切換通訊高
/低波特率時,請先將 RS-485 的通訊線拔除後,切換高/低波特率開
關,更改驅動器的通訊波特率
(09-01)為開關相對應的波特率,才能真正切換完成。若
先切換高
/低波特率開關,未先將 RS-485 的通訊線拔除,即使更改驅動器的通訊波特
(09-01)為開關相對應的波特率,ERROR 燈雖還是顯示正常,但實際上通訊功能無
效。
 
端子名稱
 
說明
 
POWER 
指示燈
 
電源指示燈,當多功能擴充卡(
EMV-APP01)與驅動器的連接正
確,才會亮燈。
 
ERROR 
指示燈
 
通訊指示燈,當多功能擴充卡(
EMV-APP01)與驅動器可以通訊
時,會亮燈;當無法正常通訊時,此燈會閃爍。
 
HIGH/LOW 
開關
 
擴充卡波特率切換開關。
 
HIGH:設置擴充卡的通訊波特率為 115200。 
LOW:設置擴充卡的通訊波特率為 9600。 
5V 
輸出電源
 500mA Max 
GND 
類比信號共同端子
 
NOTE
 
GND 僅與多功能擴充卡(EMV-APP01)上的 5V、SO1、SO2、
MI7~MIB 使用,請勿與驅動器上的控制端子 DCM 混淆。 
SO1-GND 
SO2-GND 
多功能類比電壓輸出端子
 0~10.0V(輸出電流:2mA Max) 
類比輸出量由參數