Chapter 4  Configuration 
RIC-155 Installation and Operation Manual 
4-18 Additional 
Tasks
 
 
Table 4-2.  STM-1/OC-3c Port Status Parameters 
Parameters Description Values 
Uplink Connector 
Type 
Type of the  
STM-1/OC-3c 
interface connector 
•  Two BNC – BNC coaxial connector 
•  SC – Fiber optic SC connector 
•  ST – Fiber optic ST connector 
•  FC – Fiber optic FC connector 
•  SF1 – SF1 fiber optic interface 
•  SF2 – SF2 fiber optic interface 
•  SF3 – SF3 fiber optic interface 
Section SONET/SDH 
section status 
•  Normal – Normal 
•  LOS – Loss of Signal is detected 
•  LOF – Loss of Frame is detected 
Line  
SONET/SDH line 
status 
•  Normal – Normal 
•  AIS – Alarm Indication Signal is detected 
•  RDI – Remote Defect Indication is detected 
Path SONET/SDH 
path 
status 
•  Normal – Normal 
•  AIS – Alarm Indication Signal is detected 
•  RDI – Remote Defect Indication is detected 
•  LOP – Loss of Pointer is detected 
•  Trace Mismatch – Tx path trace mismatch is detected 
Line Indication 
 
•  Normal – Primary/management link operates properly 
•  Major – A major alarm is detected on the uplink 
•  Minor – A minor alarm is detected on the uplink 
4.6 Additional 
Tasks 
Changing the Password 
From the User Access menu change current passwords and display the list of users 
and their access levels. Currently the following permanent user names are available 
(case-sensitive): SU and USER with 1234 as default password. 
 
To change the current password: 
1.  Follow the path: Configuration > System Configuration > Management > 
Management Access > User Access
The User Access menu is displayed (see 
2.  From the User Access menu, select the following: 
 
Change Password
 to assign a new password to the existing user name (SU 
or USER). Password can contain up to eight characters.