RAD Data comm ARC-101 Manuale Utente

Pagina di 46
Chapter 4.  Software Management
ARC-101 Installation & Operation Manual
4-10
Performance Monitoring Window
E3 Link Status Window
LOS
Loss of Signal
OOF
Out of Frame
LOC
Loss of Cell Delineation
AIS
Alarm Indication Signal
RDI
Remote Defect Indicator
A '0'' in the "Last Sec" columns of the Alarms listed above, indicates that no errors have occurred. A '1' in the
"Last Sec." column indicates that there are one or more errors in the last second. The number in the "All"
column is equal to the cumulative number of seconds in which errors occurred.
BIP
Bit Interleaved Parity
FEBE
Far End Block Error
E1 Link Status Window
LOC
Loss of Cell Delineation
A '0'' in the "Last Sec" columns of the Alarms listed above, indicates that no errors have occurred. A '1' in the
"Last Sec." column indicates that there are one or more errors in the last second. The number in the "All"
column is equal to the cumulative number of seconds in which errors occurred.
ATM Traffic
Monitoring
ATM cell statistics are displayed in this window - the number of events that
have occurred since counters reset or overflow in the right and left
modules:
• 
Cells transmitted
• 
Cells received
• 
Cells discarded due to HEC errors
ATM STATUS
Left Module
Last Sec.
All
Right Module
Last Sec.
All
Cells
Transmitted:
1200
412000
Cells
Transmitted:
1990
412010
Cells
Received
1208
412020
Cells
Received
1990
412000
Cells
Discarded:
Cells
Discarded:
(HEC errors)
0
0
(HEC errors)
0
0
Time since the last Counters Reset:
00:34:46
Press ESC to exit