Promise Technology M300p Manuale Utente

Pagina di 322
Chapter 4: Management with WebPAM PROe
153
Spare Drive
Spare Drive Information
When a physical drive in a disk array fails and a spare drive of adequate capacity 
is available, the disk array will begin to rebuild automatically using the spare 
drive. See “Critical & Offline Disk Arrays” on page 286.
The Spare Drive–Information tab provides information about the selected 
physical disk drive.
Spare ID – Consecutive number assigned when the spare drive was created. 
Physical Drive ID – The ID number of this physical drive. 
Spare Type – Global, can be used by any disk array. Dedicated, can only be 
used by the assigned disk array. 
Revertible – Yes or No. A revertible spare drive automatically returns to its 
spare drive assignment after the failed physical drive in the disk array is 
replaced. 
Spare Check Status – The result of the Spare Check function. Healthy or Not 
Checked. 
Physical Capacity – Theoretical capacity of the drive in GB. 
Configurable Capacity – Capacity of the drive in GB actually available for 
use. 
Block Size – Sector size in bytes. 
Drive Type – SATA or PATA. 
Model – Drive Manufacturer's model name and/or number. 
Location – The enclosure and slot number where the spare drive is 
physically installed. 
Configuration Status – Type of spare drive: Global, Revertible Global, 
Dedicated, Revertible Dedicated. 
Operational Status – OK is normal. Can also show Rebuilding or Offline. 
Serial Number – From the drive manufacturer. 
Firmware Version – From the drive manufacturer. 
Locate a Spare Drive
To locate a spare drive in the VTrak subsystem enclosure:
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click on the Spare Drives 
 icon. 
3.
Click on the Spare Drive 
 icon. 
4.
In Management View, click on the spare drive in the graphic.