Yamaha AW4416 Manuale Utente

Pagina di 507
Chapter15—MIDI
240
        
— Operation Guide
Using MIDI Clock to synchronize the 
AW4416 and a MIDI sequencer
Here we will explain how MIDI Clock (and Song Position Pointer) messages can 
be transmitted from the AW4416 instead of MTC, and used to synchronize an 
external MIDI sequencer. Use this method if the MIDI sequencer or rhythm 
machine you wish to synchronize with the AW4416 does not support MTC, or if 
you wish to specify the locate positions in terms of measures/beats.
1. Use a MIDI cable to connect the AW4416’s MIDI OUT connector to the 
MIDI IN connector of your MIDI sequencer.
2. Press the [MIDI] key, and then press the [F1] key.
The MIDI Setup screen will appear in the display.
3. Move the cursor to the OUT button of the MIDI OUT SEL. area, and 
press the [ENTER] key.
The MIDI OUT SEL. buttons select whether the MIDI OUT/THRU connector will 
function as a MIDI OUT connector (when the OUT button is on) or as a MIDI 
THRU connector (when the THRU button is on). In this example we will turn on 
the OUT button, in order to output the MIDI clock that is generated inside the 
AW4416.
MIDI IN connector
MIDI OUT/THRU connector
PROFESSIONAL AUDIO WORKSTATION
AW4416
MIDI clock master
MIDI clock slave
MIDI sequencer