Yamaha AW4416 Manuale Utente

Pagina di 507
124
        
— Reference Guide
SCENE screen
Scene Mem page
Store or recall a scene
[Function]
Store the current settings of the 
AW4416 into scene memory, or 
recall a scene that was stored in 
scene memory.
[Key operation]
• [SCENE] key → [F1] (Scene 
Mem) key
• Repeatedly press the [SCENE] 
key until the screen shown at the 
right appears.
[Mouse operation]
M button → SCEN button → Scene 
Mem tab
[Screen functions]
A
TITLE EDIT button
Use this to edit the name (library title) of a scene 
stored in the library. When you move the cursor 
to the TITLE EDIT button and press the [ENTER] 
key, the TITLE EDIT popup window will appear, 
allowing you to input the name. You can input a 
library name of up to 16 characters. For details 
on inputting characters, refer to page 60 of the 
Operation Guide.
It is not possible to change the name of scene 
number 0 or of a scene in which PROTEC-
TION is turned on. Also, numbers in which 
no scene has been stored will be displayed as 
“No Data!,” and their title cannot be edited.
B
RECALL button
Recall the currently selected scene from the 
scene list. This is the same function as the 
[RECALL] key of the top panel SCENE MEMORY 
section.
If you select a number in which nothing has 
been stored and attempt to recall it, an error 
message of “ERROR NO DATA TO RECALL” 
will be displayed, and recall will not be pos-
sible.
C
STORE button
Store the current settings (current scene) of the 
AW4416 into scene memory. This is the same 
function as the [STORE] key of the SCENE 
MEMORY section.
4
5
6
8
9
1
2
3
7