Preset Dynamics Program Parameters
The “Release”, “Hold”, and “Decay” values shown in the following table are valid when the AW4416 is set at
a sampling frequency of 44.1 kHz.
a sampling frequency of 44.1 kHz.
No.
Name
Type
Parameter
Value
Description
001
A.Dr.BD
"CMP
Compressor
Threshold (dB)
–24
Compressor that gives the best
results with an acoustic bass drum.
results with an acoustic bass drum.
Ratio ( :1)
3
Attack (ms)
9
Outgain (dB)
5.5
Knee
2
Release (ms)
58
002
A.Dr.BD
"EXP
Expander
Threshold (dB)
–23
Expander for the same purpose as
program 001.
program 001.
Ratio ( :1)
1.7
Attack (ms)
1
Outgain (dB)
3.5
Knee
2
Release (ms)
70
003
A.Dr.BD
"GAT
Gate
Threshold (dB)
–11
Gate for the same purpose as
program 001.
program 001.
Range (dB)
–53
Attack (ms)
0
Hold (ms)
1.93
Decay (ms)
400
004
A.Dr.BD
"CPH
CompanderH
Threshold (dB)
–11
Hard compander for the same
purpose as program 001.
purpose as program 001.
Ratio ( :1)
3.5
Attack (ms)
1
Outgain (dB)
–1.5
Width (dB)
7
Release (ms)
192
005
A.Dr.SN
"CMP
Compressor
Threshold (dB)
–17
Compressor that gives the best
results with an acoustic snare
drum.
results with an acoustic snare
drum.
Ratio ( :1)
2.5
Attack (ms)
8
Outgain (dB)
3.5
Knee
2
Release (ms)
12
006
A.Dr.SN
"EXP
Expander
Threshold (dB)
–23
Expander for the same purpose as
program 005.
program 005.
Ratio ( :1)
2
Attack (ms)
0
Outgain (dB)
0.5
Knee
2
Release (ms)
151
007
A.Dr.SN
"GAT
Gate
Threshold (dB)
–8
Gate for the same purpose as
program 005.
program 005.
Range (dB)
–23
Attack (ms)
1
Hold (ms)
0.63
Decay (ms)