Chapter 4: Management with WebPAM PROe
119
Enclosure
Enclosure Information
The Enclosure–Information tab provides a diagram showing the status and 
location of key components. Status information about the VTrak subsystem 
enclosure, including:
SEP Firmware Version 
Polling Interval* 
Enclosure Warning and Critical temperature thresholds* 
Controller Warning and Critical temperature thresholds* 
Power Supply Units – Device ID, Status, Fan status, and Fan speed 
Blowers (scroll fans in the cooling unit(s) – Device ID, Status, and Speed 
Voltage Sensors – 3.3V, 5.0V, and 12.0V 
Temperature Sensors – The number of sensors varies among VTrak models 
To access Controller information:
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click on the Enclosures 
 icon. 
3.
Click on the Enclosure 
 icon. 
For information on Enclosure problems, see “Chapter 8: Troubleshooting” on 
page 261.
Enclosure Settings
The Enclosure–Settings tab enables you to make settings for certain components 
of the VTrak subsystem enclosure. To make Enclosure settings:
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click on the Enclosures 
 icon. 
3.
Click on the Enclosure 
 icon. 
4.
Click on the Settings tab in Management View. 
5.
Enter a polling interval (15 to 255 seconds) in the Polling Interval field. 
6.
Enter a value in the Enclosure Warning Temperature Threshold field (45°C is 
the default). 
7.
Enter a value in the Enclosure Critical Temperature Threshold field (51°C is 
the default). 
8.
Enter a value in the Controller Warning Temperature Threshold field (63°C is 
the default). 
9.
Enter a value in the Controller Critical Temperature Threshold field (68°C is 
the default).