Zhone Technologies 600 Manuale Utente

Pagina di 240
1-4 
Server Cards
Model No.
Running Head
ADPCM Card User Screens and Settings
ADPCM Card
Table 1-2.  ADPCM Card Main Screen Actions
Table 1-3 summarizes the ADPCM card configuration parameters and available settings. 
These are also described in the following paragraphs.
Table 1-3.  ADPCM Card Setting Options and Defaults
STATE
The State setting determines whether the port is active or inactive. When assigning ADPCM 
engine pairs for WAN traffic, set the State setting to stdby (standby) for ports that are not yet 
used or not yet configured. Set it to actv (active) for ports that are ready for use.
Setting the State to rdnt (redundant) for any port on an unused card will cause that card to act 
as the redundant back-up for all of the other ADPCM cards in that unit. Once a card is 
designated as a redundant ADPCM card the only way it can be used for regular ADPCM 
traffic is to change the state of the selected port back to either actv or stdby.
When assigning ADPCM engine pairs from user cards, changing the port from stdby to actv 
and saving the selection information on the user card screen will cause the system to 
automatically assign an ADPCM engine.
When the engine is assigned from a user card, no changes can be made from the ADPCM card 
screen to any of the fields.
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Redraws the current screen with the latest information.
pg_Left
Pages through the 64 engines (highest to lowest), 8 at a time.
pg_riGht
Pages through the 64 engines (lowest to highest), 8 at a time.
SWitch
Switches an active ADPCM card to its redundant mate.
Main
Returns to the ADPCM Card Main Screen. If changes are made to settings 
and not saved, users will be prompted to save or lose changes.
Parameter
User Options
Default
STATE
stdby     actv     rdnt
stdby
USER
n/a     uX-1 through uX-8
n/a
WAN/SERV
n/a     w1-1     w1-2     w2-1     w2-2     w3-1    w3-2     w4-1     w4-2
none
TS
n/a     01-24     01-31
01
ADPCM W/S
w1-1     w1-2     w2-1     w2-2     w3-1     w3-2     w4-1     w4-2
none
ADPCM TS
01-24     01-31
01
TYPE
n/a    v&s     v     trnsp
v&s
RATE
n/a     24K     32K     40K
24K
SIG MODE
n/a     e&m     fxs     plar     fxo     user
e&m
CODING
n/a     u-law     a-inv
u-law
TC CGA
n/a     idle     busy
idle