Motorola MCF5281 Manuale Utente
MOTOROLA
Chapter 25. FlexCAN
25-23
Programmer’s Model
25.5.3 FlexCAN Control Register 1 (CANCTRL1)
Table 25-11 describes the CANCTRL1 fields.
Table 25-9. CANCTRL0 Field Descriptions
Bits
Name
Description
7
BOFFMSK
Bus off interrupt mask. The BOFF MASK bit provides a mask for the bus off interrupt.
0 Bus off interrupt disabled.
1 Bus off interrupt enabled.
0 Bus off interrupt disabled.
1 Bus off interrupt enabled.
6
ERRMSK
Error interrupt mask. The ERRMSK bit provides a mask for the error interrupt.
0 Error interrupt disabled.
1 Error interrupt enabled.
0 Error interrupt disabled.
1 Error interrupt enabled.
5–3
—
Reserved
2
RXMODE
Receive pin configuration control. This bit determines the polarity of the CANRX pin.
0 A logical ‘0’ is interpreted as a dominant bit; a logical ‘1’ is interpreted as a recessive bit.
1 A logical ‘1’ is interpreted as a dominant bit; a logical ‘0’ is interpreted as a recessive bit.
0 A logical ‘0’ is interpreted as a dominant bit; a logical ‘1’ is interpreted as a recessive bit.
1 A logical ‘1’ is interpreted as a dominant bit; a logical ‘0’ is interpreted as a recessive bit.
1–0
TXMODE
Transmit pin configuration control. This bit field controls the configuration of the CANTX pin. See
Table 25-10.
Table 25-10.
Table 25-10. Transmit Pin Configuration
TXMODE[1:0]
Transmit Pin Configuration
00
Full CMOS
1
; positive polarity (CANTX= 0 is a dominant level)
1
Full CMOS drive indicates that both dominant and recessive levels are driven by the chip.
01
Full CMOS
; negative polarity (CANTX = 1 is a dominant level)
1X
Open drain
2
; positive polarity
2
Open drain drive indicates that only a dominant level is driven by the chip. During a recessive
level, the CANTX pin is disabled (three stated), and the electrical level is achieved by external
pull-up/pull-down devices. The assertion of both Tx mode bits causes the polarity inversion to
be cancelled (open drain mode forces the polarity to be positive).
level, the CANTX pin is disabled (three stated), and the electrical level is achieved by external
pull-up/pull-down devices. The assertion of both Tx mode bits causes the polarity inversion to
be cancelled (open drain mode forces the polarity to be positive).
7
6
5
4
3
2
1
0
Field
SAMP
—
TSYNC
LBUF
LOM
PROPSEG
Reset
0000_0000
R/W
R/W
Address
IPSBAR + 0x1C_0007