Motorola MC68VZ328 Manuale Utente

Pagina di 376
11-12
MC68VZ328 User’s Manual
Programming Model
11.2.8  
RTC Interrupt Enable Register
The RTC interrupt enable register (RTCIENR) is used to enable the interrupts in the RTCSIR if the 
corresponding bit is set. The settings for the RTCIENR register are described in Table 11-10 on 
page 11-13. For
 information about the frequency of the real-time interrupts, refer to Table 11-9.
MIN
Bit 1
Minute Flag—If enabled, this bit is set every 
increment of the minute counter in the TOD 
clock.
0 = No 1-minute interrupt occurred.
1 = A 1-minute interrupt has occurred.
SW
Bit 0
Stopwatch Flag—If enabled, the stopwatch 
flag is set when the stopwatch minute count-
down times out.
0 = The stopwatch did not time out.
1 = The stopwatch timed out.
Table 11-9.   Real-Time Interrupt Frequency Settings
Real-Time 
Interrupt 
Frequency
32.768 kHz 
Reference Clock
 38.4 kHz 
Reference Clock
RFE7
512 Hz
1.9531 ms
600 Hz
1.6666 ms
RFE6
256 Hz
3.9062 ms
300 Hz
3.3333 ms
RFE5
128 Hz
7.8125 ms
150 Hz
6.6666 ms
RFE4
64 Hz
15.625 ms
75 Hz
13.3333 ms
RFE3
32 Hz
31.25 ms
37.5 Hz
26.6666 ms
RFE2
16 Hz
62.5 ms
18.75 Hz
53.3333 ms
RFE1
8 Hz
125 ms
9.375 Hz
106.6666 ms
RFE0
4 Hz
250 ms
4.6875 Hz
213.3333 ms
Table 11-8.   RTC Interrupt Status Register Description (Continued)
Name
Description
Setting