19-10
MC68VZ328 User’s Manual
AC Electrical Characteristics
19.3.7  
DRAM Write Cycle 16-Bit Access (CPU Bus Master)
Figure 19-7 shows the DRAM write cycle timing diagram for 16-bit access (CPU bus master). The signal 
values and units of measure for this figure are found in Table 19-9 on page 19-11. Detailed information 
about the operation of individual signals can be found in Chapter 7, “DRAM Controller,” and Chapter 6, 
“Chip-Select Logic.” 
Figure 19-7.   DRAM Write Cycle 16-Bit Access (CPU Bus Master) Timing Diagram
12
CASx asserted before column address 
invalid
50
ns
13
RASx negated after CASx is negated
28
ns
14
RASx precharge time (SLW= 0,1)
58,118
ns
Note:
RASx stands for RAS0 and RAS1. CASx stands for CAS0 and CAS1.
Note:
MSW is bit 5, SLW is bit 3, and BC[1:0] comprises bits 13–12 in the DRAMC register. When the table 
identifies these bits, the sequence of their listed values corresponds to the sequence of timing data provided.
Table 19-8.   DRAM Read Cycle 16-Bit Access (CPU Bus Master) Timing Parameters (Continued)
Number
Characteristic
(3.0 ± 0.3) V
Unit
Minimum
Maximum
MD[12:0]
RASx
CASx
OE
D[15:0]
DWE
1
4
5
12
6
8
13
7
14
2
3
11
9
10
Column
Row
Row