4  FRONT PANEL OPERATION 
All controls and indicators of the RTAU including the jack accesses for a selected DS1 signal 
are located on the front panel (Figure 3). The controls and indicators are described in Table 2. 
Table 2. RTAU Front Panel Description 
INDICATOR 
COLOR 
DESCRIPTION 
STATUS  
Red 
Module failure. 
 Yellow 
LED 
test. 
 
Green 
Module operating normally. 
B8ZS / AMI 
Green 
Indicates that the user has selected B8ZS line code for the bipolar 
interface. 
 
Yellow 
Indicates that the user has selected AMI line code for the bipolar 
interface. 
 
Off 
Indicates that the user has selected the internal signal monitor 
generator at the RTAU. 
Intrusive Test 
Yellow 
LED test. 
 
Green 
Indicates that the selected test mode of the RTAU is intrusive. 
 
Off 
No intrusive testing in progress. 
SWITCH 
DESCRIPTION 
LINE CODE 
This is a pushbutton switch that toggles the DS1 interface between B8ZS, AMI, or 
the internal signal monitor generator at the RTAU. When B8ZS has been selected, 
the B8ZS/AMI LED will turn green; when AMI has been selected, the B8ZS/AMI 
LED will turn yellow; when the internal signal monitor generator at the RTAU is 
selected, the B8ZS/AMI LED will turn off. Using this switch overrides the Craft 
Interface RTAU Line Code field setting. 
BIPOLAR 
ACCESS JACKS 
 
DESCRIPTION 
DS1 RX 
Bantam jack connection from DS1 receive to test equipment. Bipolar DS1 signals 
from external test equipment can be applied to the RX jack for testing. 
DS1 TX 
Bantam jack connection from DS1 transmit to test equipment. Bipolar DS1 signals 
from external test equipment can be applied to the TX jack for testing. 
 
Note: The DS1 RX and DS1 TX jacks may be used with 22 AWG Plastic Insulated 
Cable (PIC) up to 655 feet in length. Access for drop or insert of DS1 signals 
towards the network (DS3 interface) or toward the customer (DS1 distribution 
modules) for monitoring and intrusive testing is configured through the Craft 
Interface or the TL1 interface.