© 2004, ADC Telecommunications, Inc. 
Table 4. TL1 Commands Used for the RTAU 
COMMAND 
DESCRIPTION 
CHG-ACCMD-T1 
Change Access Mode T1 
CHG-LPBK-T1 
Change Loopback T1 
CHG-TSTSIG-T1 
Change Test Signal T1 
CONN-TACC-T1 
Connect Test Access T1 
DISC-MEAS Disconnect 
Measurement 
DISC-TACC 
Disconnect Test Access Metallic/Digital 
DISC-TSTSIG Disconnect Test Signal 
MEAS-SIG-T1 
Measure Signal T1 
REPT-RSLT Report 
Result 
TST-INSERRBITS 
Test Insert Error Bits 
7 SPECIFICATIONS 
The technical specifications for the RTAU modules are given in Table 5. 
Table 5. RTAU Specifications 
PARAMETER 
SPECIFICATION 
REMARKS 
Input Power
 
 
 
Input Current (Max.) 
175 mA at 
48 Volts 
 
Input Current (Nominal) 
100 mA at 
48 Volts 
 
Input Voltage (Nominal) 
–48 Vdc 
 
Input Voltage Range 
–42 to –60 Vdc 
 
Power Consumption / 
Dissipation (Max.) 
8.2 watts 
 
DS1 Jack Access
 
 
 
Electrical Interface 
Bipolar 
 
Termination 
100 ohms nominal 
± 5% 
 
Jack Type 
Bantam 
 
Line Code 
AMI or B8ZS 
Controlled by front panel switch 
Line Rate 
1.544 Mbps ± 130 ppm max. 
 
Dimensions
 
 
 
Height 
× Width × Depth 
9.5 
× 9.9 × 1.0 inches 
(24.1 
× 25.1 × 2.5 cm) 
 
Weight
 
12 oz. (.34 kg) 
 
Environment
 
 
 
Operating Temperature 
–40
° to 149° F (–40° to 65° C)   
Storage Temperature 
–40
° to 158° F (–40° to 70° C)   
Relative Humidity (Operating) 
5% to 95% 
No condensation 
Altitude (Operating  
or Non-operating) 
–1,312 to + 14,764 ft. 
(–
400 to +4,500 m)