The ADIC Management Console application allows you to manage multiple 
SNC 5100s from any location on your network. 
For installation and operating instructions, see the ADIC Management Console 
User Guide
.
Other Installation Issues
The SNC 5100 is 8.61" wide x 12.0" deep x 1.61" high. 
All the connectors, and the air outlets, are at one end of the unit. The air inlet 
and power switch at the other. A minimum of 3" clearance is required at the 
connector end for cables, though 4-5” is recommended. A minimum of 0.75" 
clearance at the air inlet end and a supply of air at ambient temperature and 
pressure are required. There are no side clearance requirements.
Attaching SCSI Devices
SCSI devices are attached to any of the SCSI connectors on the rear of the . 
The device types and speeds, as well as cabling, target IDs, and termination are 
discussed below.
High quality cables with the correct latches or screws must be used at all times 
to ensure reliable connections. Cables are not provided with the .
Caution
Ensure that you read this section before you attach any devices to the . A 
summary table appears at the end of this discussion.
Maximum Number of LUNs
The SNC 5100 supports up to 2048 LUNs. 
Caution
Do not attach more than 2048 LUNs to the SNC 5100. Exceeding the 2048 
LUN limit will result in unreliable behavior.