Chapter 3: Provisioning
3-7
Logging into DSL Circuits
To log into the console menu for an DSL card:
9
AIS
Alarm Indication signal on any G.703
interface
HDSL
G.SHDSL
10
LFA
Loss of Frame alarm on any G.703
interface
HDSL
G.SHDSL
11
RAI
Remote Alarm Indication on any G.703
interface
HDSL
G.SHDSL
Step
Action
1
In the Main menu screen (
), type the number 1 in the ENTER SELECTION field 
and press ENTER. The Enter line unit number field is displayed.
2
Enter a line unit number and press ENTER. The HDSL card console menus display. See the line unit 
technical practice for details on console menu usage.
3
To exit the HDSL console menus and return to the TAO Main menu screen, press CTRL+X or select Quit 
from the menu (if running HDSL unit firmware version 3.10).
Note:
 The V.24 Craft port is disabled on all HDSL cards when an EMU-830 is installed in the shelf.  An 
HDSL card craft port can be used directly if the EMU-830 is removed from the shelf. The V.24 Craft Port is 
enabled on all G.SHDSL line cards.