Testing
 
 LTPH-UM-1031-03, Issue 3
52
September 12, 2003
 H4TU-C-319 List 1
To perform the GNLB loopback test procedure:
1
Have the CO tester send the NREM (3-in-7) inband loopup code for 5 seconds. You should observe the 
NREM message on the front-panel display. (The Status LED on the front panel should be green, and the 
loopback mode should also be identified on the Monitor screen.)
2
Have the CO tester transmit a DS1 test signal towards the H4TU-C and verify that the returned (looped) signal 
to the test set is error-free. 
3
If step 2 fails, have the CO tester transmit the (3-in-5) inband loopdown code.
4
Have the CO tester send the NLOC (4-in-7) inband loopup for 5 seconds. You should observe the NLOC 
message on the front-panel display. (The Status LED on the front panel should be yellow, and the loopback 
mode should also be identified on the Monitor screen.)
5
Repeat Step 2. If the test passes, the problem is in the downstream direction. If it fails, the problem is in the 
upstream direction.
A3LB Test Procedure
The H4TU-C-319 can be looped back by sending the Addressable Office Repeater (AOR) LPBK activation code 
1111-1111-0001-1110 (FF1E) for at least 5 seconds. This causes the H4TU-C to enter the NLOC state. The 
Loopback Time-Out setting (see 
) determines the 
duration of this loopback unless it is overridden by the reception of a second identical 16-bit loopup command 
before the timer expires. When this time-out override state exists, the only way to loop the H4TU-C down is to 
issue one of the three loopdown commands listed in 
. The automatic time-out mode is restored during 
subsequent loopback sessions.
 summarizes the codes required to execute an A3LB Addressable Repeater Loopback command. All code 
sequences must be present for at least 5 seconds. 
Table 17.
A3LB Addressable Repeater Loopback Commands
Name
Binary Code
 (a)
 (Hexadecimal Equivalent)
(a) The leftmost bit arrives first in all sequences. The detection algorithm functions reliably with a random 10
-3
 Bit Error Ratio 
(BER) on the facility. The entire arming and loopback sequence can also be initiated at the remote H4TU-R location.
Description
NLOC
1111-1111-0001-1110 (FF1E)
H4TU-C loopup from NI.
CREM
0011-1111-0001-1110 (3F1E)
H4TU-C loopup from CI. 
NREM
1111-1111-0000-0010 (FF02)
H4TU-R loopup from NI.
NDU1
1111-1111-0000-0100 (FF04)
Signal is looped back to the network at H4D1.
CDU1
0011-1111-0000-0100 (3F04)
DS1 signal from customer is looped back to the customer at H4D1.
NDU2
1111-1111-0000-0110 (FF06)
Signal is looped back to the network at H4D2.
CDU2
0011-1111-0000-0110 (3F06)
DS1 signal from customer is looped back tot he customer at H4D2.
D1LB
Dual loopback at H4D1.
D2LB
Dual loopback at H4D2.
CLOC
0011-1111-0000-0010 (3F02)
H4TU-R loopup from CI.
SMJK
11000-11000-11000 ...
H4TU-R loopup from NI.
SMJK
100000 100000 100000 ...
H4TU-R loopup from NI.
SMJK
1111-1111-0100-1000 (FF48)
H4TU-R loopup from NI (ESF-DL).
Loopdown
11100-11100-11100 ...
H4TU-C and H4TU-R loopdown from NI OR CI.
Loopdown
100-100-100 ...
H4TU-C and H4TU-R loopdown from NI OR CI.
Loopdown
1111-1111-0010-0100 (FF24)
H4TU-C and H4TU-R loopdown from NI OR CI (ESF-DL).