Cisco Systems 7609 Manuale Utente

Pagina di 120
Chapter 5      Removal and Replacement Procedures
Removing and Replacing the Fan Assembly
5-12
Cisco 7609 Internet Router Installation Guide
OL-5079-04
Step 9
After ensuring that all wire connections are secure, reinstall the terminal block 
cover.
Caution
To prevent a short circuit or shock hazard after wiring the DC-input power 
supply, reinstall the terminal block cover.
Caution
In a system with dual power supplies, connect each power supply to a separate 
input line. In case of a line failure, the second source will most likely still be 
available.
Step 10
Remove the tape from the circuit breaker switch handle and restore power by 
moving the circuit breaker switch handle to the On (|) position.
Step 11
Turn the power switch to the On (|) position on the power supply. Turning the 
power switch on also engages a pawl that locks the power supply in the chassis.
Step 12
Verify power supply operation by checking that the power supply front panel 
LEDs are in the following states:
INPUT OK LED is green
FAN OK LED is green
OUTPUT FAIL LED is not lit
If the LEDs indicate a power problem, see the 
.
Removing and Replacing the Fan Assembly
This section describes how to remove and replace fan assemblies for the 
Cisco 7609 Internet Router. A flat-blade or number 2 Phillips-head screwdriver is 
required to perform this procedure.