Chapter 5      Troubleshooting the Installation
Troubleshooting the Power Subsystem
5-14
Cisco 12016, Cisco 12416, and Cisco 12816 Router Installation and Configuration Guide
OL-11495-01
Additional Power Subsystem Troubleshooting Information
This section contains additional troubleshooting information to help you isolate 
the cause of a power problem.
The MBus modules powering the alphanumeric displays on the RP and line cards 
are powered by +5 VDC from the backplane. The blower modules use –48 VDC 
from the backplane. If both the RP and the blower modules are operating, all 
internal correct DC voltages are present.
Enter the show environment command at the user EXEC mode prompt to display 
temperature and voltage information for each installed card, blower module, and 
PEM as shown in this example:
router#show environment
Slot #  Hot Sensor      Inlet Sensor
         (deg C)          (deg C)
1          38.0            32.5
3          36.5            39.0
5          37.0            37.0
7          36.0            32.0
16         26.0            26.0
17         27.5            27.5
18         27.0            27.5
19         0.0     0.0
20         27.0            27.5
21         28.0            28.0
22         28.0            28.0
24         47.0            NA
29         NA              22.0
Slot #  PEM Over Temperature Sensors
24      PEM1    OK
        PEM2    OK
Slot #  Hot Sensor      Inlet Sensor
         (deg C)          (deg C)
          
29         NA              22.0
Slot #  3V      5V      MBUS 5V
        (mv)    (mv)    (mv)
1       3296    5016    5048
3       3284    4976    5000
5       3308    5008    5048
7       3296    5016    5000