Chapter 7      Maintaining the Router
Removing and Replacing a Power Bus Board Fuse
Installing the Replacement Chassis
Use the following procedure to install the replacement rack in the chassis.
Step 1
Disconnect the temporary ground connections to the replacement chassis.
Step 2
Install the chassis into the rack (see 
Step 3
Connect all ground connections to the chassis (see 
Step 4
Attach the vertical cable management troughs (see 
).
Step 5
Connect all line card interface cables using the notes and labeling you created 
when disconnecting them from the defective chassis.
Step 6
Connect power cables to the router (see 
).
Step 7
Power on the router (see 
Removing and Replacing a Power Bus Board Fuse
There are two user-replaceable fuses on the power bus board inside the power 
interface panel:
  •
The fuse labeled F1 protects the MBus controller module.
  •
The fuse labeled F2 protects the 5.1 VDC bias voltage for the current 
monitoring (Imon) signal and the voltage monitoring (Vmon) signals on AC 
power subsystems.
Note
Fuse F2 is used only in AC-input power shelves. It is not used in DC-input power 
shelves. Spane fuses can be ordered from Cisco as part number: 