Compatible Systems 5.4 Manuale Utente

Pagina di 313
92 
Chapter 5 - DECnet Routing & Bridging
>
Area
DECnet areas create a logical group of DECnet nodes. A DECnet area may 
include one or more physical network segments. The Area value must be 
within the range of 1 to 63.
The area information is specific to this individual router and, along with the 
Node number, uniquely identifies it on the network. If you are unsure what 
value to use here, check with your network administrator.
>
Node
Each device in an area must have a unique node number. The Node value 
must be within the range of 1 to 1023.
The node number is specific to this individual router and, along with the Area 
number, uniquely identifies it on the network. If you are unsure what value to 
use here, check with your administrator.
v Note:  Using the same Area:Node combination as an address for two 
different devices can cause difficult-to-diagnose problems on your network. 
You should carefully track the assignment of this information for devices on 
your DECnet network.
Hello Timer
DECnet hello messages tell end nodes which routers are available to route 
packets. This parameter tells the router how frequently it should send hello 
messages on its LAN interfaces.
The Hello Timer value is also inserted into the hello messages themselves. 
Once an end node has received a hello message from a router, it begins to 
track the availability of that router. If an end node does not hear an additional 
hello message within 3 timer periods, it assumes that this router is no longer 
available.
The default value for this parameter is 30 seconds.
v Note:  The Hello Timer values for individual WAN interfaces are set in 
separate windows. For more information, see the section in this chapter on 
the DECnet: WAN Configuration Dialog Box.
Routing Timer
DECnet routing messages are exchanged between routers and contain routing 
table information including node numbers, hello timer values, hop counts and 
costs. This parameter tells the router how frequently it should send routing 
messages on its LAN interfaces.
The default value for this parameter is 120 seconds.