Appendix A List of Functions Added 
 
A.5 New 
Curve 
Element 
 
Curve Input 
 
Create a Curve Input element on the screen. Set the Sample Number to 4, and Read Address 
to $0. When Read Address is set to$0, the addresses for each sample number are $0, $1, $2 and 
$3 respectively. 
 
Create four numeric entry elements on the screen and the addresses are $0、$1、$2 and $3 
respectively. After completing the property settings, perform Compile operation and download 
the screen data to the user’s HMI screen. To set the value, the user can select the desired value 
on HMI screen directly or use the numeric entry element to enter the setting value.   
A-12 