Lucent Technologies 6000 Manuale Utente

Pagina di 586
Configuring Frame Relay
Configuring 64 switched Frame Relay connections
MAX 6000/3000 Network Configuration Guide
 
   Preliminary January 4, 2001   
5-37
Ascend-Metric=2,
Ascend-FR-DLCI=16,
Ascend-FR-Profile-Name="SWITCHED-FR-DTE",
Ascend-Bridge=Bridge-No,
Ascend-Call-Type=Switched,
Ascend-Idle-Limit=120
Be sure to:
Set Ascend-Require-Auth to Not-Require-Auth.
Specify the corresponding Frame Relay Data Link profile in the Ascend-FR-
Profile-Name
 attribute.
Set Ascend-Call-Type to Switched.
Sample RADIUS CLID profile
Following is a sample RADIUS CLID profile:
3757
Password=“Ascend-CLID”
Ascend-Require-Auth=Not-Require-Auth
User-Service=Framed-User,
Framed-Protocol=FR,
Framed-Address=10.10.10.212,
Framed-Netmask=255.255.255.0,
Ascend-Route-IP=Route-IP-Yes,
Ascend-Metric=2,
Ascend-FR-DLCI=16,
Ascend-FR-Profile-Name="SWITCHED-FR-DTE",
Ascend-Bridge=Bridge-No,
Ascend-Call-Type=Switched,
Ascend-Idle-Limit=120
Be sure to:
Set Ascend-Require-Auth to Not-Require-Auth.
Specify the corresponding Frame Relay Data Link profile in the Ascend-FR-
Profile-Name
 attribute.
Set Ascend-Call-Type to Switched.
Configuring a switched Frame Relay connection for an outbound call
To support users that use switched Frame Relay connections for outbound calls, you must 
create a Route profile, a Frame Relay Data Link profile, and a user profile. 
Sample RADIUS Route profile
The MAX retrieves the following example RADIUS Route profile when it powers up or when 
you update routes by executing the Sys > Sys Diag > Upd Rem Cfg command:
route-My-MAX4000-1 Password="ascend",User-Service=Dialout-Framed-User
        Framed-Route="10.10.10.0/24 10.10.10.212 1 n switched-dte1-out"