RAD Data comm ASMi-52 Manuale Utente

Pagina di 186
Chapter 3  Operation 
Installation and Operation Manual 
3-6 Configuration 
Alternatives
 
ASMi-52 Ver. 2.5 
Parameter Default 
Value 
Serial DTE Interface 
 
Rate Single: 
2-wire – 192 kbps 
4-wire – 384 kbps 
Multiplexer: 
1. E1+Serial DTE, N/A, 0 kbps 
2. LAN+Serial DTE: 
2-wire – 192 kbps 
 
4-wire – 384 kbps 
LLB from DTE 
Disable 
RLB from DTE 
Disable 
E1/E1+Ethernet/E1+Serial DTE Interface 
Framed mode 
Unframed 
Sync CCITT 
CRC-4 No 
Idle Code 
ff 
Units identical settings 
Yes 
T1
 Interface 
 
Framed mode 
Unframed 
Line code 
B8ZS 
Receive gain 
Long 
Interface DSU 
Transmit signal mask 
0 feet 
Fbit configuration 
Transparent 
Sync mode 
Fast (after 1 sec) 
Idle code 
Ff 
Units identical set 
Yes 
 
3.4 Configuration Alternatives 
After installation, ASMi-52 can be reconfigured using different ports and 
applications: 
•  Local out-of-band management via an ASCII terminal or the Easy Config 
device connected to the RS-232 port. Usually, preliminary configuration of the 
system parameters is performed via an ASCII terminal. Once the ASMi-52 host 
IP parameters are set, it is possible to access it via Telnet, ConfiguRAD, or 
RADview-Lite for further configuration.