Module and Fan Installation
NIM IOM Installation
NIM IOM Installation
1. From the chassis rear, place the NIM IOM in slot B so that it slides easily in 
the top and bottom card guides with the connector aligned to the midplane 
connector. 
2. Visually verify that the NIM IOM physically aligns with the NIM installed 
above. 
3. Firmly press the NIM IOM into the chassis until the connectors completely 
seat. 
4. Secure the retaining screws on the top and bottom of the module, being careful 
not to over-tighten.
5. Repeat this process for the NIM IOM in slot A.
SAM IOM Installation
1. From the chassis rear, place each SAM IOM so that it slides easily in the top 
and bottom card guides with the connector aligned to the midplane connector 
for the slot matching the corresponding SAM.
2. Visually verify that the SAM IOM physically aligns with the SAM installed 
above. 
3. Firmly press the SAM IOM into the chassis until the connectors completely 
seat. 
4. Secure the retaining screws on the top and bottom of the module, being careful 
not to over-tighten.
5. Repeat this process for each slot with a corresponding SAM installed. 
Protection SAM IOM Installation
1. From the chassis rear, place the Protection SAM IOM so that it slides easily in 
the top and bottom card guides with the connector aligned to the midplane 
connector for the slot matching the corresponding SAM in slot P. 
2. Visually verify that the Protection SAM IOM physically aligns with the SAM 
installed above.