Safety Guide [IP8800/S6700]
vii
■ Grounding is required.
• When the device is connected to the power supply of 100VAC, leak current of up to 3.5mA flows for each 
device. Be sure to use the grounded outlet. If the power supply is used without grounding, an electric shock 
may be caused and failures may occur due to electric noise.
• When the device is connected to the power supply of 200VAC, leak current of up to 5mA flows for each 
device. Choose a grounded outlet and make sure that the outlet is grounded to a ground plate in the 
building. Request the maintenance personnel or specialized installation workers to check the grounding. If 
the power supply is used without grounding, an electric shock may be caused and failures may occur due 
to electric noise. The label below is attached to the device.
• When the device is connected to the DC power supply, be sure to connect the grounding terminal. If the 
power supply is used without grounding, an electric shock may be caused and failures may occur due to 
electric noise.
■ Installing/uninstalling of the DC power cable must be performed by the trained 
engineer or maintenance personnel.
• Installing/uninstalling of the DC power cable must be performed by the trained engineer or maintenance 
personnel. DC power cable is connected to the power supply via a terminal. Therefore, inadvertent 
handling of the DC power cable may result in fire disasters or electric shock.
■ Before installing or removing a DC power cable, turn off the breaker on power supply 
facilities.
• Before installing or removing a DC power cable, turn off the breaker on power supply facilities. Operation 
with the breaker on may cause electric shock.
■ Attach insulation covers on the 0V and -48V terminals of a DC power cable.
• Attach insulation covers on the 0V and -48V terminals of a DC power cable (the side of which connects to 
power supply facilities). Operation without insulation covers may cause electric shock.
■ When using the DC power supply, do not leave the terminal board uncovered.
• When using the DC power supply, be sure to attach the cover to the terminal board after connecting the 
power cable. Operating it without the terminal board cover can cause an electric shock.
■ Do not touch the potential tap.
• The power supply is provided with the potential tap. This tap is used for inspection at shipment. Customer 
should not use this tap. Do not insert a sharp material such as pin or clip into the potential tap. Fire disasters 
or electric shock may be caused.