Troubleshooting Functional Failures in Operation
35
3.4.6
Communication Failure on Using PoE
If electricity is not provided when PoE is in use, isolate the problem using the failure analysis methods listed in the 
following table.
Table 3-12: Communication Failure Analysis Methods When PoE Is in Use
3
According to the failure 
statistical information displayed 
by the show interfaces 
command, check to see if the 
statistical information below is 
counted for the port. If counted, 
see "Problem" and "Action" 
columns. [IP8800/S6700] 
[IP8800/S6600] [IP8800/
S6300]
• 
RF
Line quality on 
sending side is 
degraded.
Check the type of fiber optics. For the fiber optics type, see "Hardware 
Installation Guide."
Check the attenuation value if an optical attenuator is used. For the 
optical level, see "Hardware Installation Guide."
Check the cable length. For the cable length, see "Hardware Installation 
Guide."
Check to see if the cable is connected correctly. Check to see if end 
surfaces of the cable are dirty. If they are dirty, remove the dirt.
Check to see if the transceiver is connected correctly.
For the transceiver, follow the segment standard on the remote system.
Check to see if the optical level is correct. For the optical level, see 
"Hardware Installation Guide."
Perform the line test on this system and confirm that there is no problem 
in the sending function. See the execution results of the no test 
interfaces command and follow the indicated actions. For the test 
type to be specified, see "
."
4
According to the failure
statistical information displayed 
by the show interfaces 
command, check to see if the 
statistical information below is 
counted for the port.
 If counted, see "Problem" and 
"Action" columns.
• Long frames
Packets with 
invalid frame 
length are received.
Follow the jumbo frame setting on the remote system.
5
Check to see if statistics in the 
following is not counted by the 
show qos queueing 
command. If it is counted, see 
"Problem" and "Action" 
columns.
• discard_pkt
Packets are being 
discarded.
Review the system maintenance using discard control and shaper.
No.
Troubleshooting Steps and Command
Action
1
Check to see PoEStatus display on the port by 
the show power inline command.
• PoEStatus indicates off
Electricity is not provided. Go to No.2.
• PoEStatus indicates denied
A shortage of electricity to the whole equipment occurs. Go to No.3.
• PoEStatus indicates faulty
Electricity is unable to be provided to the connected equipment. Go to No.4.
2
Check to see if the port is shutdown.
• The port is shutdown
Use the no shutdown command.
• The port is not showdown
Check to see if Power receiving equipment is connected properly.
No.
Troubleshooting Steps
Problem
Action