NEC IP8800/S2400 Manuale Utente

Pagina di 250
3.   
Troubleshooting Functional Failures in Operation
111
When using SNMPv3
Execute the show snmp-server command to confirm that the information on the SNMP manager and trap has 
been registered in the configuration for this system. If it is not correctly registered, execute the configuration 
command below to set up the information on the SNMP manager and trap.
• snmp-server engineID local
• snmp-server view
• snmp-server user
• snmp-server group
• snmp-server host
 
(config)# show snmp-server
  snmp-server engineID local "engine-ID"
  snmp-server group "v3group" v3 priv notify "view1"
  snmp-server host   20.1.1.1 traps "v3user" version 3 priv snmp
  snmp-server user "v3user" "v3group" v3 auth md5 "abc*_1234" priv des "xyz/
+6789"
  snmp-server view "view1" 1.3.6.1 included
  !
(config)#
In some SNMP manager systems, "ospf" or "bgp" traps issued by SNMPv2C or SNMPv3 may not be received. For 
such systems, review the trap receiving settings on the SNMP manager in accordance with object ID for each trap 
described in "MIB Reference."