3.   
Troubleshooting Functional Failures in Operation
114
Figure 3-23: Display Example of Configuration 3
(config)# show interfaces
interface gigabitethernet 1/2
  switchport mode access
  sflow forward ingress      <- sflow forward must be set here.
!
(config)#
 
• See  "
" to confirm that "filter" is not set for the physical 
port subject to flow statistics.
• Specifying Source IP address for sFlow packets with "sflow source," check to see if the IP address is 
assigned to the port of this system.
Figure 3-24: Display Example of Configuration 4
(config)# show sflow
sflow destination 192.1.1.1 6455
sflow sample 2048
sflow source 192.1.1.100  <- This IP address must be one assigned to the port of 
this system.
!
(config)#
 
(4) Checking NIF/port status
Execute the show interfaces command to check that up/down status of the physical port of this system or the 
physical port connecting to the collector to be monitored by sFlow statistics is "active" (normal operation).
Figure 3-25: Display Example of Port Status
> show interfaces gigabitethernet 1/5
Date 2006/10/24 17:19:34 UTC
NIF1: active  48-port 10BASE-T/100BASE-TX/1000BASE-T    retry:0
        Average:150Mbps/24Gbps  Peak:200Mbps at 15:44:37
Port5: active up  100BASE-TX full(auto)    0012.e220.ec31
  Time-since-last-status-change:1:47:47
    Bandwidth:10000kbps  Average out:5Mbps  Average in:5Mbps
    Peak out:5Mbps at 15:44:36  Peak in:5Mbps at 15:44:18
    Output rate:    4893.5kbps       16.8kpps
    Input  rate:    4893.5kbps       16.8kpps
    Flow control send   :off
    Flow control receive:off
    TPID:8100
                             :
>
 
Note: Confirm that "active" or "active up" is displayed at the underlined part.
 
If the port status is DOWN, see "
(5) Checking settings of collector
• Confirm that the UDP port number (default: 6343) on the collector side is available to receive packets. 
If the port is not ready for receiving packets, ICMP ([Type]Destination Unreachable [Code]Port Unreachable) will 
be transmitted to this system.
• Confirm that other settings on the collector used are correct.