NEC IP8800/S3600 Manuale Utente

Pagina di 250
3.   
Troubleshooting Functional Failures in Operation
29
Figure 3-2: Example of "Checking Port Operation Status" [IP8800/S6700] [IP8800/S6600] [IP8800/S6300]
> show port statistics
2006/03/23 12:00:00
Port Counts:48
Port  Name    Status  T/R   Unicast   Multicast   Broadcast     Discard
1/ 1  geth1/1  up     Tx          0           0           0           0
                      Rx          0           0           0           0
1/ 2  geth1/2  down   Tx          0           0           0           0
                      Rx          0           0           0           0
1/ 3  geth1/3  down   Tx          0           0           0           0
                      Rx          0           0           0           0
(Omitted hereafter)
>
Figure 3-3: Example of "Checking Port Operation Status" [IP8800/S3600] [IP8800/S2400]
> show port statistics
2006/03/23 12:00:00
Port Counts:48
Port  Name    Status  T/R All packets   Multicast   Broadcast     Discard
0/ 1  geth0/1  up     Tx            0           0           0           0
                      Rx            0           0           0           0
0/ 2  geth0/2  down   Tx            0           0           0           0
                      Rx            0           0           0           0
0/ 3  geth0/3  down   Tx            0           0           0           0
                      Rx            0           0           0           0
(Omitted hereafter)
>
If display item "Discard" is larger than 0 when this command is executed, a failure discarding packets has occurred. Use 
the show interfaces command to retrieve detail information of the port.
3.4.2
Communication Failure in Basic Switching Unit BSU/PSP
If BSU/PSP has possibly caused the communication failure, check for the BSU/PSP status as follows.
(1) Checking BSU/PSP operation status
1. Checking log
For the log, see the manual "Message Log Reference."
2. Isolating the problem according to the BSU/PSP operation status
Check the BSU/PSP operation status by using the show system command, and isolate the problem according to 
the table below.
Table 3-8: Check and Action for BSU/PSP Operation Status
No.
BSU Operation
Status
Problem
Action
1
active
The BSU/PSP is operating as active system.
2
standby hot
The BSU/PSP is operating  as standby system 
in hot standby mode.
3
standby cold
[IP8800/S6700]
The BSU/PSP is operating as standby system 
in cold standby mode.
4
standby cold2
[IP8800/S6700]
[IP8800/S6600]
The BSU/PSP is operating as standby system 
in cold standby 2 mode.