NEC 151944 Manuale Utente

Pagina di 78
CHAPTER 3
ND-46550 (E)
 
Page 64
Revision 2.0
(2)
When using CN connector on DAIA Card
Connect the cable to a CSU or directly to the Remote PIM via the CN connector on the DAIA/DAIC card as
shown in 
. Connection of DAIC cards between the Main PIM and the Remote PIM is available in
the same manner as the DAIA-DIAB connection.
Figure 3-39    DTI Cable Connection via CN Connector (Main Site)
CSU
MDF
TWISTED-PAIR
CABLE
DAIA
BWB
MAIN PIM
(SHIELD TYPE)
CN
DAIA/DAIC
MDF
CN
TB
TA
RB
RA
TO CSU/REMOTE PIM
SEND
RECEIVE
4
3
2
1
BA1
AA1
BA0
AA0
TB
TA
RB
RA
CN CONNECTOR
(0.65
Φ 
cable)
Note 1:
When the Remote PIM is directly connected without CSU, maximum distance is 1312 ft. (400 m)
between the Main PIM and the Remote PIM.
Note 2:
When the DAIA card is mounted in the MP/FP slot, be sure to connect the cable to the CN con-
nector on the DAIA card.
Note 1
MAX.656 ft. (200 m)
/
DAIC