PN-DAIC (DAIC)
RUN lamp is not flashing Abnormal operation of 
DAIC card
➀ Reset MB switch.
(Down
Up
Down)
➁ If the fault can not be cleared, 
replace card.
LINK lamp is not on
Layer 2 link connection 
failure between DAIA and 
DAIB
➀ Check whether cable between 
DAIA and DAIB is correctly 
connected. (Refer to 
➁ Reset MB switch
(Down
Up
Down)
③ Check whether cable between 
DAIC cards is correctly 
connected. (Refer to 
RED lamp is on
PCM signal loss or Frame 
Alignment signal loss
➀ Check whether cable between 
DAIC cards is correctly 
connected. (Refer to 
RMT lamp is on
Remote alarm
➀  Check whether cable between 
DAIC cards (sending side) is 
correctly connected. (Refer to 
Table 4-1  Remedial Action on Each Lamp Status (Continued)
CARD NAME
LAMP STATUS
FAULT CONTENT