Siemens SM2 monitoring system Manuale Utente

Pagina di 500
U3585-J-Z125-8-76
85
Statements for SM2 administrators
MODIFY-COSMOS-PARAMETER
Operands
TITLE =
Specifies the title of the COSMOS monitoring process.
TITLE = *UNCHANGED
The currently specified title is not changed.
TITLE = <c-string 1..80>
The specified title is assigned.
BUFFER-SIZE =
Specifies the number of 4K pages per buffer.
*SPECIFIED(...)
,JOB-NAME = *NOT-SPECIFIED / list-poss(8): <alphanum-name 1..8 with-wild>
,CATEGORY = *NOT-SPECIFIED / list-poss(8): <alphanum-name 1..7 with-wild>
,USER-ID = *NOT-SPECIFIED / list-poss(8): <alphanum-name 1..8 with-wild>
 TSN = *NOT-SPECIFIED / list-poss(16): <alphanum-name 1..4 with-wild>
,TYPE = *NOT-SPECIFIED / list-poss(4): *SYSTEM / *DIALOG / *BATCH / *TP
*SPECIFIED(...)
EIA-INTERRUPT-CLASS = *UNCHANGED / *ANY / list-poss(5): *SVC / *PROGRAM /
                                              *MACHINE-CHECK / *IO / *EXTERNAL

,EIA-SVC-NUMBER = *UNCHANGED / *ANY / list-poss(8): <integer 1..255>



,MEMORY-CLASS = *UNCHANGED / *ANY / list-poss(4): *3 / *4 / *5 / *6

,SLOT-MEMORY-CLASS = *UNCHANGED / *ANY / list-poss(4): *3 / *4 / *5 / *6


,LOCK-ID = *UNCHANGED / *ANY / list-poss(4): <alphanum-name 1..2>

,TLT-DESCRIPTOR = *UNCHANGED / *ANY / list-poss(8): <alphanum-name 1..3>


,TSVC-SVC-NUMBER = *UNCHANGED / *ANY / list-poss(8): <integer 1..255>
,UNLOAD = *UNCHANGED / *AT-MEASUREMENT-PROGRAM-STOP / *AT-SM2-STOP
,MEASUREMENT-TIME = *UNCHANGED / *NOT-SPECIFIED / <integer 1..60>
(part 2 of 2)