5. Appendix 
13 
1/13/2011 5:38 PM 
Cable Connectors 
 
 
 
Cabling must have a male XLR connector on one end and a female XLR 
connector on the other end. 
 
 
 
 
 
Do not allow contact between the common and the fixture’s chassis ground. Grounding 
the common can cause a ground loop, and your fixture may perform erratically. Test 
cables with an ohm meter to verify correct polarity and to make sure the pins are not 
grounded or shorted to the shield or each other. 
 
 
 
Setting the Starting Address 
 
 
 
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a 
start address from 1~512. A fixture requiring one or more channels for control begins to read the 
data on the channel indicated by the start address. For example, a fixture that uses six DMX 
channels and was addressed to start on DMX channel 100, would read data from channels: 100, 
101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap, 
and note the start address selected for future reference. 
 
If this is your first time addressing a fixture using the DMX control protocol, we suggest jumping 
to the “Appendix” section and reading the heading “DMX Primer”. It contains very useful 
information that will help you understand its use. 
 
 
 
 
 
 
COMMON 
DMX + 
DMX
 - 
INPUT 
OUTPUT 
1 
3 
2 
1 
3 
2 
1 
3 
2 
120 ohm ¼ W resistor 
between pin 2 (DMX -) and 
pin 3 (DMX +) on the 
output of the last fixture 
To avoid signal transmission problems 
and interference, it is always advisable to 
connect a DMX signal terminator. 
DMX connector configuration 
Terminator