Peerless Industries PRG-1S Manuale Utente

Pagina di 13
ISSUED: 08-15-07  SHEET #: 055-9491-7  06-11-11
Visit the Peerless Web Site at www.peerlessmounts.com
6 of 13
For customer care call 1-800-865-2112 or 708-865-8870.
Installation to Concrete Ceilings
Place projector mount assembly (A) on ceiling 
as a template and mark the center of the two 
mounting holes. Drill two 5/16" (8mm) dia. holes 
to a minimum depth of 2-1/2" (64mm). Attach 
projector mount assembly (A) using two concrete 
anchors (G), two fl at washers (E), and two #14 x 
2-1/2" wood screws (F) as shown in Illustration A 
and 12 and 3).
NOTE: Mounting slots on projector mount 
assembly allow for 30° (±15°) of swivel adjustment 
before fully securing wood screws.
Tighten wood screws (F) using 3/8" (10mm) socket 
or open end wrench or phillips screwdriver until 
projector mount assembly (A) is fi rmly attached.
1
•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Make sure that the supporting surface will safely support the combined load of the equipment and all attached 
hardware and components.
 WARNING
•  Always attach concrete anchors directly to load-
bearing concrete.
•  Never attach concrete anchors to concrete covered 
with plaster, drywall, or other fi nishing material. 
If mounting to concrete surfaces covered with a 
fi nishing surface is unavoidable (not evaluated by 
UL), the fi nishing surface must be counterbored 
as shown below. Be sure concrete anchors do not 
pull away from concrete when tightening screws. If 
plaster/drywall is thicker than 5/8", custom fasteners 
must be supplied by installer (not evaluated by UL).
 WARNING
•  Tighten wood screws fi rmly, but do not overtighten. 
Overtightening can damage the screws, greatly 
reducing their holding power.
•  Never tighten in excess of 80 in • lb (9 N.M.).
 WARNING
Illustration A
G
F
E
A
CONCRETE CEILING
ARROW ON TOP 
OF PROJECTOR 
MOUNT ASSEMBLY  
INDICATES FRONT 
OF MOUNT
CUT
A
W
A
Y
 VIEW
A
CORRECT
plaster/
dry wall
concrete
INCORRECT
plaster/
dry wall
concrete
A
1
3
2
G
Drill holes and insert anchors (G).
Place plate (A) over anchors (G) and secure with screws (F).
Tighten all fasteners.
A
G
F
concrete
surface