Sanyo PLC-XU350 Manuale Utente

Pagina di 79
6
When  the  projection  lamp  of  the  projector  reaches  its  end
of  life,  the  Lamp  replacement  icon  appears  on  the  screen
and  LAMP  REPLACE  indicator  lights  yellow.  Replace  the
lamp with a new one promptly. The timing when the LAMP
REPLACE  indicator  should  light  is  depending  on  the  lamp
mode.
Follow these steps to replace the lamp.
For  continued  safety,  replace  with  a  lamp  of  the
same  type.  Do  not  drop  a  lamp  or  touch  a  glass
bulb! The glass can shatter and may cause injury.
Allow a projector to cool for at least 45 minutes
before you open the Lamp Cover. The inside of
the projector can become very hot.
CAUTION
Unplug the AC power cord. Let the projector cool for at
least 45 minutes.
Loosen the three (3) screws that secure the lamp. Lift
the lamp out of the projector by using the handle.
1
3
Replace the lamp with a new one and secure the three
(3) screws. Make sure that the lamp is set properly.
Close the lamp cover and secure the screw.
4
Loosen the screw and open the lamp cover.
Connect the AC power cord to the projector and turn
on the projector.
5
Lamp Replacement
CAUTION
Top Control
LAMP REPLACE 
indicator
Lamp
Screw
Handles
Screw
Lamp Cover
Screw
Screw
CAUTION
When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be
broken.
If replacing the lamp of a projector which has been installed on the ceiling, you should always assume that
the  lamp  is  broken,  and  you  should  stand  to  the  side  of  the  lamp  cover,  not  underneath  it.  Remove  the
lamp cover gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces of glass get
into your eyes or mouth, seek medical advice immediately.
✔ 
Note:
• When Mode 2 is selected in the Lamp life control menu, if the projection lamp of the projector reaches its
end of life, the lampreplacement icon appears on the screen, and the projector is turned off automatically
after 3 minutes.
• The Lamp replacement icon will not appear when the Display function is set to Off (p.46), during Freeze
(p.25), or No show (p.26).
Lamp replacement icon
Maintenance and Cleaning