18NOV97 – SM5440-1
Adjusting the CLAMP PAD ASSEMBLY
Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the removal for the LOWER HOUSING
ASSEMBLY.
Important
It is necessary to make a FAN COVER TOOL. See the
Tools section.
Tools section.
[3] Install the FAN COVER TOOL over the FAN area
and the LAMP MODULE. See the Tools section.
[4] Connect the REMOTE CONTROL ASSEMBLY
EC-3 to the REMOTE RECEPTACLE.
Warning
Dangerous Voltage
[5] Connect the main power.
[6] Loosen the NUT on the CLAMP PAD ASSEMBLY.
[7] Energize the REMOTE FOCUS in either direction.
[8] Rotate the SCREW on the CLAMP PAD
ASSEMBLY to adjust the pressure of the
REMOTE FOCUS CLAMP on the CLAMP PAD
ASSEMBLY until the CLAMP PAD ASSEMBLY
does not move.
REMOTE FOCUS CLAMP on the CLAMP PAD
ASSEMBLY until the CLAMP PAD ASSEMBLY
does not move.
[9] Release the REMOTE FOCUS.
[10] Tighten the NUT on the CLAMP PAD ASSEMBLY.
[11] Install the AUTO-FOCUS GAUGE TL-1744 in the
MECHANISM GATE. The CLAMP PAD
ASSEMBLY should move forward and backward
using TL-1744. If not, adjust the SCREW on the
CLAMP PAD ASSEMBLY again; the CLAMP PAD
ASSEMBLY adjustment is too tight and not
correct.
ASSEMBLY should move forward and backward
using TL-1744. If not, adjust the SCREW on the
CLAMP PAD ASSEMBLY again; the CLAMP PAD
ASSEMBLY adjustment is too tight and not
correct.
Adjustment Specification
The PRESSURE PAD should be aligned with the DARK SHUTTER.
Adjusting the DARK SHUTTER
[1] Do the removal for the LOWER HOUSING.
[2] Insert a thin SLIDE into the GATE MECHANISM; the DARK SHUTTER should open.
[3] Check the the PRESSURE PAD is correctly aligned with the the DARK SHUTTER.
[4] Bend the PRESSURE PAD to adjust the alignment.
A091_4041GA
A091_4041GCA
SCREW
NUT
CLAMP PAD