General Troubleshooting 
 
 
 
S
YMPTOM
 
P
OSSIBLE 
C
AUSE
(
S
P
OSSIBLE 
A
CTION
(
S
Breaker/Fuse 
keeps blowing 
·
  Excessive circuit load 
·
  Check total load placed on the 
electrical circuit. 
·
  Short circuit along the power 
wires 
·
  Check for a short in the electrical 
wiring (internal and/or external). 
Device does not 
power up 
·
  No power 
·
  Check for power on Mains. 
·
  Loose power cord 
·
  Check power cord 
Fixture is not 
responding to DMX 
·
  Wrong DMX addressing 
·
  Check Control Panel and unit 
addressing  
·
  Damaged DMX cables 
·
  Check DMX cables 
·
  Wrong polarity settings on the 
controller 
·
  Check polarity switch settings on 
the controller 
·
  Loose DMX cables 
·
  Check cable connections 
·
  Faulty DMX interface 
·
  Replace DMX input 
·
  Faulty Main PCB 
·
  Replace Main PCB 
Loss of signal 
·
  Non DMX cables 
·
  Use only DMX compatible cables 
·
  Bouncing signals 
·
  Install terminator as suggested. 
·
  Long cable / Low level signal 
·
  Install amplifier right after fixture 
with strong signal.  
·
  Too many fixtures 
·
  Install an optically coupled DMX 
splitter after unit #32. 
·
  Interference from AC wires 
·
  Keep DMX cables separated from 
power cables or black lights. 
 
   
 
If you still have a problem after trying the above solutions, please contact CHAUVET® 