Execute Errors
 269
65 
CREATE page starting row PAGE SR out of bounds
When you specify the position of the page parameters with the 
Page command in the Create Form mode, the row position 
specified will place the page number above or below the 
boundaries of the form. When this error occurs, the IGP will 
automatically revert to the Normal mode.
66 
CREATE page starting column PAGE SC out of bounds
When you specify the position of the page parameters in the 
Create command, the column position specified will place the 
page number outside the form boundaries. When this error 
occurs, the IGP will automatically revert to the Normal mode.
67 
CREATE STOP command missing
This error occurs when the IGP receives a new function 
command, an End command, or a mode command without 
receiving a Stop command. The IGP will continue to process 
subsequent commands correctly. 
68
Insufficient memory to store the SETUP program
No more room in the IGP/PGL memory exists for storing the 
SETUP routine. 
69
Insufficient memory to store the form
The directory is full, or no more room exists in the IGP memory 
for another form. When this occurs, the IGP automatically reverts 
to the Normal mode. To create space in the IGP memory, delete 
forms that are no longer required. 
Execute Errors
70 
EXECUTE form count parameter FC error
This error occurs when the parameter specifying the number of 
blank forms to print was entered incorrectly. When this error 
occurs, the IGP will automatically revert to the Normal mode. 
Form count can be from 1 through 65,535.
71 
EXECUTE/DELETE form not found in the directory
An attempt was made to execute or delete a form which does not 
exist in the forms directory. When this error occurs, the IGP 
reverts to the Normal mode. 
72 
EXECUTE EVFU load error
This error is generated only during the Execute Form mode while 
programming the EVFU. If more channels than lines per physical 
page are specified during a load sequence, this error is 
generated, and the IGP reverts to the Normal mode.
73 
EXECUTE EVFU terminator invalid
This error is generated only during the Execute Form mode. The 
EVFU LOAD is missing an END LOAD code. If the line terminator 
cannot be deciphered, an error is generated, and the IGP reverts 
to the Normal mode.