RibbonMinder
Print Statistics
You can view various printer statistics, such as hours of usage, and refer to 
these figures for preventive maintenance purposes. Printer statistics 
accumulate continuously; they do not reset when you turn off the printer.
All of the printer statistics are set to zero at the factory after burn-in testing.
On. The cumulative time in hours the printer has been powered on. The 
range is from 0 to 30,000 hours.
Print. The cumulative time in hours the printer has actually been printing. 
The range is from 0 to 30,000 hours.
Print Strokes. The cumulative number of back-and-forth shuttle strokes 
the printer has printed during normal operation. The range is from 0 to 
2,147,483,648 shuttle strokes.
Print Lines. The cumulative number of lines the printer has printed. The 
range is from 0 to 2,147,483,648 print lines.
11 inch Pages. The cumulative number of pages the printer has printed. 
The range in print pages is from 0 to 2,147,483,648 total inches of paper 
movement divided by 11.
RibbonMinder
RibbonMinder is a user-definable software feature which notifies the user 
when a ribbon should be changed. It does this by monitoring ink consumption 
and alerts you when the print quality falls below a level you designate. This is 
especially important if you are printing bar codes to be scanned.
As printing continues, the percentage of usable ink in the ribbon decreases.
When 0% usable ink appears, the printer is typically configured to stop 
printing and display the following message:
ON LINE
100%
<printer emulation>
ON LINE
 74%
Ribbon ink being consumed
<printer emulation>
ON LINE
  8%
Ribbon life approaching end
<printer emulation>
RIBBON INK OUT
CHANGE RIBBON