Printronix P5000LJ Manuale Utente

Pagina di 336
 68
Chapter
3
Configuring NIC
Configuration Using The Printer Control Panel
NIC settings can be set from the printer control panel. The procedure is 
described below.
You can set any of three listed parameters from the printer control panel. 
These parameters are located in the ETHERNET PARAMS menu. The 
available parameters are:
IP Address
Gateway Address
Subnet Mask
The procedure for changing any of the parameters is the same. The 
procedure for changing the IP Address is given here as an example. Use the 
same procedure for the other required parameters.
To change the IP Address parameter:
1.
Make sure the printer is on and raise the printer cover.
2.
Press the ON LINE key to place the printer in the OFFLINE mode.
3.
Unlock the ENTER key. (For instructions, refer to “Locking And Unlocking 
The ENTER Key” on page 48.)
4.
Press the LEFT or RIGHT arrow key until the LCD displays “ETHERNET 
PARAMS.”
5.
Press the DOWN arrow key to access the “IP Address” parameter.
6.
Press the DOWN arrow key to view the current IP Address.
7.
Press the DOWN arrow key to access the portion of the IP Address to be 
changed.
8.
Press the LEFT or RIGHT arrow key to select the portion of the IP 
Address to be changed.
Note
Some network environments do not require any network settings to be 
configured on the NIC. However, all network setups require configuration 
on the host end.
Note
When the printer is first powered on, the messages “Waiting for the 
Ethernet Adapter” and “Ethernet Detected” will display on the LCD. After 
several other boot messages appear, the LCD will display the message
“E-NET INIT.” This initialization process will take about two minutes. 
During that time, you will not be able to change any printer settings from 
the control panel. If you attempt to do so, the message “Please Wait 
E-NET INIT.” will appear. When the initialization is complete, the message 
“E-NET READY” will display, and you may then change any NIC or other 
printer configuration options from the control panel.