Philips 5900 Manuale Utente

Pagina di 160
Management and Configuration
102
AXIS 5900 User’s Manual
Follow the instructions below to add a string after the print job:
1. From the print server’s internal Web page, select 
Admin | Logical Printer 
Settings.
2. Select the 
Printer5 tab.
3. Enter the string 
04 in the String After Print Job text field.
4. Click the 
OK button.
Example:
Follow the instructions below to add strings before and after the print job:
1. From the print server’s internal Web page, select 
Admin | Logical Printer 
Settings.
2. Select the 
Printer4 tab.
3. Enter the string 
1B 26 6C 34 48 in the String Before Print Job text field.
4. Enter the string 
1B 26 6C 31 48 in the String After Print Job text field.
5. Click the 
OK button.
String Substitutions
The string substitution function performs search and replace operations 
on the print data. The primary application is to replace printer control 
commands. Up to twenty string substitutions may be specified 
individually for each logical printer.
All strings must be entered as hexadecimal byte values, and each match 
and substitute string must be preceded by a count byte. 
You substitute command strings by editing the String Substitutions 
(PRx_STR) parameter.
Example:
Follow the instructions below to substitute command strings:
1. From the print server’s internal Web page, select 
Admin | Logical Printer 
Settings.
2. Select the 
PR1 Webeb page.
3. Enter the string 
01 0A 02 0D 0A in the String Substitutions text field.
You have an HP LaserJet printer with dual input bins, and want to print on 
pre-printed forms when using the logical printer PR4. The standard forms are 
taken from bin 1, and the pre-printed forms are taken from bin 2. The string 
before print job should contain the command to select bin 2, 
E
C
l4H
 (hex 
1B 
26 6C 34 48
), and the string after print job should contain the command to 
select bin 1, 
E
C
l1H
 (hex 
1B 26 6C 31 48
).
Assume that you want to replace the UNIX New Line (hex 
0A
) with an ASCII 
NewLine (hex 
0D 0A
) for logical printer PR1.