M-S Cash Drawer 7193 Manuale Utente

Pagina di 118
7193 Owner’s Guide
Diagnostics
May 1996
Diagnostics
The following diagnostic tests are available for the 7193:
• 
Level 0 Diagnostics
Performed during the startup cycle
• 
Level 1 Diagnostics (setup mode)
Available in a dedicated environment and accessed through the DIP Switches
• 
Level 2 Diagnostics
Performed during normal printer operation
Level 0 Diagnostics
The printer performs level 0 diagnostics during the startup cycle when power is
supplied or the printer is brought on-line. Level 0 diagnostics comprise the
following actions:
• 
Motors are turned off
• 
Microprocessor timing is checked, CRC check of the firmware ROM is
performed, external RAM is read (failure causes level 0 diagnostics to stop;
the printer beeps once when the test is successfully completed)
• 
Checks if paper is present
• 
Homes knife (failure causes a fault condition)
• 
Checks if receipt cover is closed (failure does not interrupt the startup cycle)
When the last step is complete, the Paper Feed button is enabled and the printer
is ready for normal operation. Information about the test is available to the
communication interface through the commands.
If the printer has not been turned on before, or a new EEROM has been installed,
the default values for the printer settings (set in Level 1 Diagnostics) will be
loaded into the EEROM. The printer beeps twice when this occurs. See the tables
in “Level 1 Diagnostics” for the printer settings. If the printer beeps twice at any