Symptom
 
Action
 
The
 
server
 
unexpectedly
 
shuts
 
down,
 
and
 
the
 
LEDs
 
on
 
the
 
operator
 
information
 
panel
 
are
 
not
 
lit.
 
See
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
on
 
the
 
IBM
 
System
 
x
 
Documentation
 
CD.
  
Serial
 
port
 
problems
 
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
Problem
 
Determination
 
and
 
Service
 
Guide
 
on
 
the
 
IBM
 
System
 
x
 
Documentation
 
CD
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Symptom
 
Action
 
The
 
number
 
of
 
serial
 
ports
 
that
 
are
 
identified
 
by
 
the
 
operating
 
system
 
is
 
less
 
than
 
the
 
number
 
of
 
installed
 
serial
 
ports.
 
1.
   
Make
 
sure
 
that:
 
v
   
Each
 
port
 
is
 
assigned
 
a
 
unique
 
address
 
in
 
the
 
Configuration/Setup
 
Utility
 
program
 
and
 
none
 
of
 
the
 
serial
 
ports
 
is
 
disabled.
 
v
   
The
 
serial
 
port
 
adapter
 
(if
 
one
 
is
 
present)
 
is
 
seated
 
correctly.
2.
   
Reseat
 
the
 
serial
 
port
 
adapter.
 
3.
   
Replace
 
the
 
serial
 
port
 
adapter.
 
A
 
serial
 
device
 
does
 
not
 
work.
 
1.
   
Make
 
sure
 
that:
 
v
   
The
 
device
 
is
 
compatible
 
with
 
the
 
server.
 
v
   
The
 
serial
 
port
 
is
 
enabled
 
and
 
is
 
assigned
 
a
 
unique
 
address.
 
v
   
The
 
device
 
is
 
connected
 
to
 
the
 
correct
 
connector
 
(see
 
2.
   
Reseat
 
the
 
following
 
components:
 
a.
   
Failing
 
serial
 
device
 
b.
   
Serial
 
cable
 
c.
   
Remote
 
Supervisor
 
Adapter
 
II
 
SlimLine
 
(if
 
one
 
is
 
present)
3.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
Failing
 
serial
 
device
 
b.
   
Serial
 
cable
 
c.
   
Remote
 
Supervisor
 
Adapter
 
II
 
SlimLine
 
(if
 
one
 
is
 
present)
 
d.
   
(Trained
 
service
 
technician
 
only)
 
System
 
board
 
 
Chapter
 
5.
 
Solving
 
problems
 
87