Zebra Technologies P640i Manuale Utente

Pagina di 93
980541-001 Rev. A
P640i Card Printer User Guide
51
Flip station components: Upside down views of 
the carrier, 
drive 
component
s omitted. 
Flip 
station 
motor: Viewed from the back of the printer. A 
pinion on the motor shaft engages the rack at 
the rear of the carrier, above.
 
Flip 
station 
viewed 
from 
above: 
Points to 
note: 
1.  The 
stop 
pin 
(integr
al with 
the rear 
flipper 
arm) rests on the bottom edge of the carrier, 
alternating from one side to the other in 
consecutive flip cycles
2. Azimuth adjust rotates the entire assembly to 
bring the flipper arms parallel to the carriage - a 
very sensitive adjustment
3. The arms must move freely,  without end float. 
Over tightening of the screws will lock the arms. 
Card held by flip arms : As the carriage moves 
into the flip station, the card slides into grooves in the 
flip arms. The entire flip assembly is then elevated 
clear of the platen. 
Flip 
station 
adjustm
ent 
procedu
re 
The flip 
station 
requires no 
routine 
maintenance 
other than 
occasional 
vacuuming 
out of debris. 
Typically, there should be no need to alter the factory 
settings. 
If the flip station ceases to function, or functions 
erratically, the technician should perform the 
following tests before replacing components. 
1. Power OFF. 
Remove all cards
 from the hopper, then 
close the hopper cover. Disable the main cover 
interlock so that the printer will function with the 
cover open. Power ON. 
2. On the host computer follow this sequence:
Start
 > Printers (or Printers and Faxes) > Right 
click Zebra P640i > Properties > Device Settings 
> Control > 
Advanced Utilites
 
3. Click Move Truck to Flip Station. 
4. With the flip arms horizontal, click 
Flip Test 3
 (No 
Flip) a few times, noting what happens as the 
carrier begins to elevate at the start of the flip 
cycle. 
This is a test for clearance between flip arms and 
platen. If the arms touch the platen, even lightly, there 
will be tendency for one or both of them to rotate a 
little as the carrier rises. The arms 
must
 be parallel to 
the platen, with a few thousandths of an inch clearance 
each side. Using a flashlight, check the gap by 
inserting a 0.004" (0.01 mm) feeler gauge between 
each arm and the platen. (A narrow strip of regular 
copier paper can be used instead, but a long metal 
feeler gauge is better.) 
Caution • Cards thicker than 0.033" 
(0.84 mm) may jam in the flipper arms.