Page Setup
Parameters Used
10/05/2009
TTP 7030™ Technical Manual
P1003636-002
Parameters Used
Parameter n35 Black Mark
Enables/disables black mark check.
Parameters n37 and n38 - Page Length Minimum 
Measure the distance from the trailing edge of one black mark to the trailing edge of the next. 
The resolution is 0.125 mm so multiply the distance by 8, then calculate the value to enter as 
n37 and n38.
Parameter n39 – Max Black Mark Length
Measure the height of the black mark. The resolution is 0.125 mm so multiply the black mark 
length (in millimeters) by 8 and enter the value as n39.
Parameter n40 – Min Black Mark Length (Garbage Filter)
This parameter is actually a filter to filter-out garbage on the paper. If a spot is smaller than this 
value, it will not be regarded as a black mark. 1. About ⅓ of the black mark length is usually a 
suitable setting.
 
Example • 
If the page length is 100mm, (100 x 8) / 256 = 3.125. 
n37 is the integer value, that is 3, while 
n38 is the fraction, 0.125 x 256 = 32