Zebra Technologies R-140 Manuale Utente

Pagina di 126
I·Code Tags
I
Code labels are also high frequency (13.56MHz) devices but have 512
bits of storage capacity. Data is addressed in sixteen blocks of 32 bits, each
block containing four bytes. The first two blocks of data (block 0 and 1) are
used for storage of a unique 64 bit serial number. The next two blocks
(blocks 2 and 3) are used for storage of configuration information; block 4
is used for family or application identification and blocks 5 to 15 are free
for user application use.
If you are using I
Code tags for your own use, and don’t require universal
special function or family codes, then you can program blocks 3 through 15.
I
Code Blocks
Block #
Description
Bytes
0
Serial Number (write protected)
1
Serial Number (write protected)
2
Write Protect Block (Caution!)
3
Special Function Block
8 Optional
4
Family Code
5
User Data
40 User
6
User Data
7
User Data
8
User Data
9
User Data
10
User Data
11
User Data
12
User Data
13
User Data
14
User Data
15
User Data
8
Zebra R-140 User’s Guide