2 Troubleshooting Procedures
2.3 Power Supply Troubleshooting
Procedure 2
Error Code Check
If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The
blink pattern indicates an error as shown below.
blink pattern indicates an error as shown below.
Start Off
for
2
seconds
Error code (8 bit)
“1”
On
for
one
second
“0”
On
for
a
half
second
Interval between data bits Off
for
a
half
second
The error code begins with the least significant digit.
Example: Error code = 12h (Error codes are given in hexadecimal format.)
2-8
Satellite M30-35 Maintenance Manual (960-455)