2  Troubleshooting Procedures 
2.6  2.5” HDD Troubleshooting 
Procedure 2 
Message Check 
When the power is turned on, the system performs the Initial Reliability Test (IRT) installed 
in the BIOS ROM. When the test detects an error, an error message is displayed on the screen. 
Turn on the computer and check the message on the screen. When an OS starts from the 2.5” 
HDD, go to Procedure 3. Otherwise, start with Check 1 below and perform the other checks as 
instructed. 
Check 1  If any of the following messages appear, go to Procedure 3. If the following 
messages do not appear, perform Check 2. 
HDC ERROR
 
 
or 
HDD #X ERROR     
(After 5 seconds this message will disappear.)
  
Check 2  If either of the following messages appears, go to Check 3. If the following 
messages do not appear, perform Check 4. 
Insert system disk in drive 
Press any key when ready ..... 
or 
Non-System disk or disk error 
Replace and press any key when ready 
Check 3  Using the SYS command of the MS-DOS, transfer the system to the 2.5” HDD. If 
the system is not transferred, go to Procedure 3. Refer to the MS-DOS Manual for 
detailed operation. 
If the following message appears on the display, the system program has been 
transferred to the HDD. 
System Transferred 
If an error message still appears on the display, perform Check 4. 
Check 4  The 2.5” HDD and the connector of the system board may be disconnected. Insert 
the connectors firmly. (Refer to the steps described in Chapter 4, Replacement 
Procedures
 for disassembling.) If they are firmly connected, go to Procedure 3. 
QOSMIO F10  Maintenance Manual (960-498) 
 