New commands: 
The percentage of main memory used for big pages can be changed 
with the new command MODIFY-MEMORY-PARAMETERS. The command SHOW-
MEMORY-CONFIGURATION displays the current configuration of main 
memory, including the use of big pages. 
 
  *1 
The two new parameters/commands are only available on SX150  
  *1 
servers. They are ignored on S systems and on SX100, SX130 and  
  *1 
SX140 servers. 
The command MODIFY-MEMORY-PARAMETERS is rejected with the message 
EMM2350. 
 
  *2 
- ISAM parameter set 
 
  *2 
Discontinued parameter: 
  *2 
The parameters GLBDFPS, DFPPROC, GLBDFPN are no longer evaluated 
  *2 
as of BS2000/OSD-BC V6.0B due to the modified default mechanism 
  *2 
for NK-ISAM-Pools 
 
  *2 
New parameter: 
  *2 
The new parameter MAXDSBN defines the maximum number of DATA 
  *2 
SPACES that are generated for task-independent NK-ISAM-Pools. 
  *2 
A range from 1 to 127 can be specified, the default value is 2. 
 
System generation: 
 
It is not necessary to generate the software for BS2000/OSD-BC 
V6.0. The organization program SYSPRG.BS2.150 is part of the re-
lease unit BS2000-EXEC. 
The utility program UGEN is no longer supplied.  
The product IOGEN has been used for generating the I/O configura-
tion data since BS2000/OSD V5.0B. 
As of IOGEN V15.0A, tape devices with DVC type CC (LTO-U2) can be 
generated. 
Note: If an IOCF with DVC type CC is used on a system with 
BS2000/OSD V5.0B, the correction A0502425-001 is absolutely im-
perative. 
 
System address space: 
 
The limitation to system address space by the selected SYSSIZE 
has been eliminated since BS2000/OSD-BC V5.0. The system also 
uses less address space by moving internal tables into data 
spaces.